Water Mist Pump
Custom built with installation in mind:
When seeking a water mist pump that delivers to recognised and approved industry standards to protect your property and loved ones, it’s important to note the following:
Protect your home
Our sleek compact pump unit can be connected directly to the mains water and includes an on board monthly self-test and manual test facility.
The control board monitors the pumps and is equipped with fire and fault N/O and N/C relays for use with third party equipment (e.g. alarms and fire panels).
Passes the Test
A Fully Compliant Pump Unit
Our Water Mist Pump system meets the safety requirements of BS:8458 Residential Water Mist Standards and has been tested against the performance fire tests of BS:9252 Sprinkler Standards.
Independently tested by Warrington Fire, a UKAS accredited laboratory.
Specifications
What’s the Features
The pump has been designed by the specialist team at iCO®, therefore it’s built with both ergonomic and highly specific considerations.
Fire Resistance – The pump enclosure is now completely constructed from steel providing fire resistance and additional resistance against mechanical damage.
Serviceability – The new pump has a removable cover so that the internal components can be serviced and maintained in the field by the installing company. Pumps can now be repaired in the field rather than being sent back to the manufacturer which will save on costly revisits.
Integrated Inlet/Outlet Manifolds – All of the inlet manifold (Strainer, low pressure switch, actuated ball valve) and outlet manifold (isolation valve, pressure gauge, drain valve) are now integrated within the enclosure. No more untidy valves and hoses.
No permanent drain required – Operation of the pump is no longer requires a permanent drain to be provided.
Wall or floor mounting – If fitted on the floor or in a cupboard the enclosure has a flat back which fits neatly against a wall. Fixing holes are provide in the back of the chassis for optional wall mounting.
* An internal LCD display is provided to indicate the status of the system.
10 – 100 bar
Working Pressure of the Pump?
Our Pump run pressure can be adjusted from 10 – 100 bar to suite different nozzles which may be used for protection of different applications.
* This is what the compact pump looks like with the robust casing removed.
continued
Even More Features
We haven’t finished yet…
Low Standing Pressure – The system now operates off a flow switch rather than a pressure switch. This means that the system will eventually drop down to mains water pressure and sit there indefinitely without calling the pumps to work. Previously any loss in pressure due to a small leak in the distribution pipework could cause the pumps to come on at undesirable times. Now the system sits at mains water pressure and will not bring the pumps on unless there is a significant flow of more than 0.5lpm.
Actuated ball valve – Previously after the pump had finished its run time it would cut power to the pumps however it would still be able to run indefinitely at mains water pressure. We have now integrated an actuated ball valve which will shut off the water supply and the power to the pumps following elapse of the selected run time.
Drip tray with float switch – There is always a risk of damage to products during transit or installation. The risk of damage to property as a result of internal components leaking is almost eliminated with the addition of a drip tray and float switch within the base of the pump enclosure. In the event of any escape of water from damaged components the float switch will operate and close that actuated ball valve to shut off the water supply to the pump.
Corrosion resistance – The internal pump components are now made of the highest quality corrosion resistant materials.
Robust operation – There are no solenoid or pressure relief valves that run to permanent drain. This avoids any problems associated with dirt under the seals which could result in a small escape of water and pumps running at undesirable times.
Adjustable pump run time – The pump runtime can be adjusted with a dil switch to suit 30min (Residential) or 10min (Domestic) depending on the category of the system.
Pre-action / Double Knock Operation – With any water based fire suppression system there is always risk of unwanted operation through accidental or malicious damage to pipework or nozzles/sprinklers. The discharge of water could be potentially damaging to the property the system is protected.
Water mist pump
Full Spec and Sizing
A compact unit that includes self-testing, means you only need to service once a year.
IPH Mist Suppression Ltd offer full-service contracts with all water mist installations.
link to smokes
Double Knock Safety Feature
When using this facility, the pumps would need to have both the smoke detection and the nozzle operate before the pumps will run.
As an additional safety measure to protect against unwanted operation and ultimately needlessley misting up your property, our custom made pump incorporates safety facility to receive an input from the smoke detection system on the pump control and monitoring board.
If just the nozzle operates, the system will not run. If just the smoke detection operates the system will not run. Both smoke (to operate the detection system) and heat (to operate the nozzle) will need to be present for the system to run.
Whilst this is an optional facility we would recommend that you use this on every installation to provide an additional level of protection against unwanted operation. The smoke detection system must be compliant with BS5839 pt6 Grade D LD1 with detection provided in every room that is protected by the mist system.
Latest News & Case Studies
Best Water Mist System Pump
Our sleek compact pump unit can be connected directly to mains water and includes an on board monthly self test and manual test facility. The control board monitors the pumps and is equipped with...
Why did we Partner with iCO?
IPH Mist Suppression have partnered with iCO who design and custom make a revolutionary fire suppression system offering discrete protection coupled with industry leading pricing, efficient system...
Water Mist Suppression for the Home
IPH was first formed in 2003 operating from a North West office base. 2014 saw the creation of IPH Fire Solutions. We have since continued to expand and in our journey to provide comprehensive...